§ 47-5.38. Table of dimensional requirements for the RMH-60 district. (Note A)  


Latest version.
  • Requirements Single
    Family
    Dwelling
    Single Family Dwelling, Attached: Duplex/Two (2) Family Dwelling Single Family Dwelling; Zero-Lot-Line Single Family Dwelling, Attached: Cluster
    See
    Section 47-18.9
    Single Family Dwelling, Attached: Townhouses Single Family Dwelling, Attached: Rowhouse:
    See
    Section 47-18.28
    Multi-
    Family
    Dwelling
    Bed and
    Breakfast
    Dwelling
    Hotel Other
    Uses
    Maximum density (du/net acre) 60 60 60 60 60 60 60
    Note D
    87 sleeping
    rooms per net
    acre (maximum
    9 sleeping
    rooms per
    dwelling)
    87 hotel rooms per net acre, up to 120 sleeping rooms per net acre** None
    Minimum lot size (sq. ft.) 5,000 5,000

    2,500 each du
    4,000 2,500 each du 7,500—avg. 2,500 per unit 2,000 per unit 5,000 5,000 10,000 10,000
    Maximum structure height (ft.) 35 35 35 35 35 55 150
    Note D
    *Up to 300 ft.
    35 150
    Note D
    *Up to 300 ft.
    150
    Note D
    *Up to 300 ft.
    Maximum structure length (ft.) None None None None 200 400 200
    (Note C)
    None None None
    Minimum lot width (ft.) 50 50 40 See Sec.
    47-18.9
    50 20 50 50 100 100
    Minimum floor area (sq. ft.) 750 400 each du 1,000 750 each du 750 each du 750 per du 400 each du 120 per
    sleeping room

    Historic designation = None
    120 per
    sleeping room
    None
    Minimum front yard (ft.) (Note B) 25 25 25 25 25 5 ft. minimum

    10 ft. maximum
    25 25 25 25
    Minimum corner yard (ft.) (Note B) 25% of lot width but not less than 10 ft. nor greater than 25 ft.

    20 feet when abutting a waterway
    Same as single family requirement

    20 ft. when abutting a waterway
    See Section 47-18.38

    20 ft. when abutting a waterway
    25% of lot width but not less than 10 ft. nor greater than 25 ft.

    20 ft. when abutting a waterway
    25% of lot width but not less than 10 ft. nor greater than 25 ft.

    20 ft. when abutting a waterway
    5

    20 ft. when abutting a waterway
    25 25 25 25
    Minimum side yard (ft.) (Note B) 5 ft. - up to 22 ft. in height

    Where a building exceeds 22 ft. in height that portion of the building above 22 ft. shall be set back an additional 1 ft. per foot of additional height.

    20 ft. when abutting a waterway
    Same as single family requirement

    20 ft. when abutting a waterway
    See Section 47-18.38

    20 ft. when abutting a waterway
    See Section 47-18.9

    20 ft. when abutting a waterway
    See Section 47-18.33

    20 ft. when abutting a waterway
    0 or 10

    20 ft. when abutting a waterway
    10

    20 ft. when abutting a waterway
    10 ft. - up to 22 ft. in height

    Where a building exceeds 22 ft. in height, that portion of the building above 22 ft. shall be set back an additional 1 ft. per foot of additional height

    20 ft. when abutting a waterway
    20 20
    Minimum rear yard (ft.) (Note B) 15

    20 ft. when abutting a waterway
    15

    20 ft. when abutting a waterway
    15

    20 ft. when abutting a waterway
    See Section 47-18.9

    20 ft. when abutting a waterway
    20 15

    20 ft. when abutting a waterway
    20 20 20 20
    Minimum distance between buildings (ft.) None None None None None 10

    20 ft. maximum when on a public street
    10 ft. or 20% of tallest building (whichever is greater) None 10 ft. or 20% of tallest building (whichever is greater) 10 ft. or 20% of tallest building (whichever is greater)

     

    Note A: Dimensional requirements may be subject to additional regulations, see Section 47-23, Specific Location Requirements, and Section 47-25, Development Review Criteria.

    Note B: Yard dimensions in this district are the minimum requirements. In no case shall the dimensional requirements be less than an amount equal to one-half (½) the height of the building, when this is greater than the above specified yard minimums. Modification of required yards may be permitted subject to the requirements of Section 47-23.11, Specific Location Requirements.

    Note C: May be increased to 300 feet subject to criteria in Section 47-23.13.

    Note D: East of the Intracoastal Waterway, maximum height is one hundred twenty (120) feet, and may be increased to two hundred forty (240) feet subject to a conditional use permit and density is forty-eight (48) dwelling units per acre.

     *Requires conditional use permit for heights greater than one hundred fifty (150) feet, up to 300 feet.

    **Site plan level III approval for hotel sleeping rooms greater than eighty-seven (87) sleeping rooms up to one hundred twenty (120) sleeping rooms per net acre, see Section 47-24.2.

(Ord. No. C-97-19, § 1(47-5.4), 6-18-97; Ord. No. C-99-21, § 1, 3-16-99; Ord. No. C-04-10, § 2, 4-7-04; Ord. No. C-17-47 , § 20, 1-3-18)