Fort Lauderdale |
Unified Land Development Code |
Article II. ZONING DISTRICT REQUIREMENTS |
Section 47-5. RESIDENTIAL ZONING DISTRICTS AND RESIDENTIAL OFFICE ZONING DISTRICTS |
§ 47-5.37. Table of dimensional requirements for the RMH-25 district. (Note A)
-
Requirements Single
Family
DwellingSingle Family Dwelling, Attached: Duplex/Two(2) Family Dwelling Single Family Dwelling: Zero-Lot-Line Single Family Dwelling, Attached: Cluster Single Family Dwelling, Attached:
TownhousesMultifamily Dwelling Bed and
Breakfast
DwellingHotel Other Uses Maximum density (du/net acre)
(Density bonus—See Section 47-23.12.)25 25 25 25 25 25 30 sleeping
rooms per net
acre (maximum 9 sleeping rooms per dwelling)30 hotel rooms per net acre None Minimum lot size (sq. ft.) 5,000 5,000
2,500 each du4,000 2,500 each du 7,500 5,000 5,000 10,000 10,000 Maximum structure height (ft.) 35 35 35 35 35 100 35 100 100 Maximum structure length (ft.) None None None None 200 200
(Note C)None 200
(Note C)200
(Note C)Minimum lot width (ft.) 50 50 40 See Section 47-18.9 50 50 50 100 100 Minimum floor area (sq. ft.) 1,000 400 each du 1,000 750 each du 750 each du 400 each du 120 per sleeping room 120 per
sleeping roomNone Minimum front yard (ft.) (Note B) 25 25 25 25 25 25 25 25 25 Minimum corner yard (ft.) (Note B) 25% of lot width but not less than 10 ft. nor greater than 25 ft.
20 ft. when abutting a waterway25% of lot width but not less than 10 ft. nor greater than 25 ft.
20 ft. when abutting a waterwaySee Section 47-18.38
20 ft. when abutting a waterway25% of lot width but not less than 10 ft. nor greater than 25 ft.
20 feet when abutting a waterway25% of lot width but not less than 10 ft. nor greater than 25 ft.
20 feet when abutting a waterway25 25% of lot width but not less than 10 ft. nor greater than 25 ft.
20 ft. when abutting a waterway25 25 Minimum side yard (ft.) (Note B) 5 ft. - up to 22 ft. in height
When a building exceeds 22 ft. in height that portion of the building above 22 ft. shall be set back an additional 1 ft. per foot of additional height.
20 ft. when abutting a waterwaySame as for single family requirement
20 ft. when abutting a waterwaySee Section 47-18.38
20 ft. when abutting a waterwaySee Section 47-18.9
20 feet when abutting a waterwaySee Section 47-18.33
20 ft. when abutting a waterway10
20 ft. when abutting a waterway10 ft. - up to 22 ft. in height
Where a building exceeds 22 ft. in height that portion of the building above 22 ft. shall be set back an additional 1 ft. per foot of additional height.
20 ft. when abutting a waterway20 20 Minimum rear yard (ft.)(Note B) 15
20 ft. when abutting a waterway15
20 ft. when abutting a waterway15
20 ft. when abutting a waterwaySee Section 47-18.9
20 feet when abutting a waterway20 20 20 20 20 Minimum distance between buildings (ft.) None None None None None 10 ft. or 20% of tallest building (whichever is greater) None 10 ft. or 20% of tallest building (whichever is greater) 10 ft. or 20% of tallest building (whichever is greater) Note A: Dimensional requirements may be subject to additional regulations, see Section 47-23, Specific Location Requirements, and Section 47-25, Development Review Criteria.
Note B: Yard dimensions in this district are the minimum requirements. In no case shall the dimensional requirements be less than an amount equal to one-half (½) the height of the building, when this is greater than the above specified yard minimums. Modification of required yards may be permitted subject to the requirements of modification of yards, Section 47-23.11.
Note C: May be increased to 300 feet subject to criteria provided in Section 47-23.13.
(Ord. No. C-97-19, § 1(47-5.4), 6-18-97; Ord. No. C-99-21, § 1, 3-16-99; Ord. No. C-17-47 , § 19, 1-3-18)