§ 47-5.36. Table of dimensional requirements for the RMM-25 district. (Note A)  


Latest version.
  • Requirements Single
    Family Dwelling
    Single Family Dwelling, Attached: Duplex/Two(2) Family Dwelling Single Family Dwelling: Zero-Lot-Line Single Family Dwelling, Attached: Cluster Single Family Dwelling, Attached: Townhouses Multifamily Dwelling Bed and
    Breakfast
    Dwelling
    Hotel Other Uses
    Maximum density (du/net acre)
    (Density bonus—See Section 47-23.12.)
    25 25 25 25 25 25 30 sleeping rooms per net acre (9 sleeping rooms maximum per dwelling) 30 hotel sleeping rooms per net acre None
    Minimum lot size (sq. ft.) 5,000 5,000

    2,500 each du
    4,000 2,500 each du 7,500 5,000 5,000 10,000 10,000
    Maximum structure height (ft.) 35 35 35 35 35 55 35 55 55
    Maximum structure length (ft.) None None None None 200 200
    (Note C)
    None 200
    (Note C)
    200
    (Note C)
    Minimum lot width (ft.) 50 50 40 See Section 47-18.9 50 50 50 100 100
    Minimum floor area (sq. ft.) 750 400 each du 1,000 750 each du 750 each du 400 each du 120 per sleeping room

    Historic designation = None
    120 per sleeping room None
    Minimum front yard (ft.)(Note B) 25 25 25 25 25 25 25 25 25
    Minimum corner yard (ft.) (Note B) 25% of lot width but not less than 10 ft. nor greater than 25 ft.

    20 ft. when abutting a waterway
    25% of lot width but not less than 10 ft. nor greater than 25 ft.

    20 ft. when abutting a waterway
    See Section 47-18.38

    20 ft. when abutting a waterway
    25% of lot width but not less than 10 ft. nor greater than 25 ft.

    20 ft. when abutting a waterway
    25% of lot width but not less than 10 ft. nor greater than 25 ft.

    20 ft. when abutting a waterway
    25 25% of lot width but not less than 10 ft. nor greater than 25 ft.

    20 ft. when abutting a waterway
    25 25
    Minimum side yard (ft.) (Note B) 5 ft. - up to 22 ft. in height

    Where a building exceeds 22 ft. in height that portion of the building above 22 ft. shall be set back an additional 1 ft. per foot of additional height.

    20 ft. when abutting a waterway
    Same as for single family requirement

    20 ft. when abutting a waterway
    See Section 47-18.38

    20 ft. when abutting a waterway
    See Section 47-18.9

    20 ft. when abutting a waterway
    See Section 47-18.33

    20 ft. when abutting a waterway
    10 10 ft. - up to 22 feet in height

    Where a building exceeds 22 ft. in height that portion of the building above 22 ft. shall be set back an additional 1 ft. per foot of additional height.

    20 ft. when abutting a waterway
    20 20
    Minimum rear yard (ft.) (Note B) 15

    20 ft. when abutting a waterway
    15

    20 ft. when abutting a waterway
    15

    20 ft. when abutting a waterway
    See Section 47-18.9

    20 ft. when abutting a waterway
    20 20 20 20 20
    Minimum distance between buildings (ft.) None None None None None 10 ft. or 20% of tallest building (whichever is greater) None 10 ft. or 20% of tallest building (whichever is greater) 0

     

    Note A: Dimensional requirements may be subject to additional regulations, see Section 47-23, Specific Location Requirements, and Section 47-25, Development Review Criteria.

    Note B: Yard dimensions in this district are the minimum requirements. In no case shall the dimensional requirements be less than an amount equal to one-half (½) the height of the building, when this is greater than the above specified yard minimums. Modification of required yards may be permitted subject to the requirements of Modification of Yards, Section 47-23.11.

    Note C: May be increased to 300 feet subject to criteria provided in Section 47-23.13.

(Ord. No. C-97-19, § 1(47-5.4), 6-18-97; Ord. No. C-99-21, § 1, 3-16-99; Ord. No. C-17-47 , § 18, 1-3-18)