§ 47-5.34. Table of dimensional requirements for the RM-15 and RMs-15 districts. (Note A)  


Latest version.
  • Requirements Single Family Dwelling Single Family Dwelling, Attached: Duplex/Two(2) Family Dwelling Single Family Dwelling: Zero-Lot-Line Single Family Dwelling, Attached: Cluster Single Family Dwelling, Attached: Townhouses Multifamily Dwelling Bed and
    Breakfast
    Dwelling
    Other Uses
    Maximum density (du/net acre) 15 15 15 15 15 15 30 sleeping rooms per net acre (maximum 9 sleeping rooms maximum per dwelling) None
    Minimum lot size (sq. ft.) 5,000 5,000

    2,500 each du
    4,000 2,500 each du 7,500 7,500 5,000 10,000
    Maximum structure height (ft.) 35 35 35 35 35 35 35 35
    Maximum structure length (ft.) None None None None 200 200
    (Note B)
    None 200
    (Note B)
    Minimum lot width 50 50 40 See Section 47-18.9 50 50 50 100
    Minimum floor area (sq. ft.) 1,000 750 each du 1,000 750 each du 750 each du 400 each du 120 per sleeping room

    Historic designation = None
    None
    Minimum front yard (ft.) 25 25 25 25 25 25 25 25
    Minimum corner yard (ft.) 25% of lot width but not less than 10 ft. nor greater than 25 ft.

    20 ft. when abutting a waterway
    25% of lot width but not less than 10 ft. nor greater than 25 ft.

    20 ft. when abutting a waterway
    See Section 47-18.38

    20 ft. when abutting a waterway
    25% of lot width but not less than 10 ft. nor greater than 25 ft.

    20 ft. when abutting a waterway
    25% of lot width but not less than 10 ft. nor greater than 25 ft.

    20 ft. when abutting a waterway
    25 25% of lot width but not less than 10 ft.

    20 ft. when abutting a waterway
    25
    Minimum side yard (ft.) 5 ft. - up to 22 ft. in height for one or two story buildings

    Where a building exceeds 22 ft. in height that portion of the building above 22 ft. shall be set back an additional 1 ft. per foot of additional height.

    20 ft. when abutting a waterway
    Same as single family requirement

    20 ft. when abutting a waterway
    See Section 47-18.38

    20 ft. when abutting a waterway
    See Section 47-18.9

    20 ft. when abutting a waterway
    See Section 47-18.33

    20 ft. when abutting a waterway
    10

    20 ft. when abutting a waterway
    10 ft. - up to 22 ft. in height

    Where a building exceeds 22 ft. in height that portion of the building above 22 ft. shall be set back an additional 1 ft. per foot of additional height

    20 ft. when abutting a waterway
    20
    Minimum rear yard (ft.) 15

    20 ft. when abutting a waterway
    15

    20 ft. when abutting a waterway
    15

    20 ft. when abutting a waterway
    See Section 47-18.9

    20 ft. when abutting a waterway
    20 20 20 20
    Minimum distance between buildings (ft.) None None None None None 10 None 10

     

    Note A: Dimensional requirements may be subject to additional regulations, see Section 47-25, Development Review Criteria.

    Note B: May be increased to 300 feet subject to criteria provided in Section 47-23.13.

(Ord. No. C-97-19, § 1(47-5.4), 6-18-97; Ord. No. C-99-21, § 1, 3-16-99; Ord. No. C-99-27, § 4, 5-4-99; Ord. No. C-17-47 , § 16, 1-3-18)