Requirements
|
Single Family Dwelling
|
Single Family Dwelling, Attached: Duplex/Two(2) Family Dwelling
|
Single Family Dwelling: Zero-Lot-Line
|
Single Family Dwelling, Attached: Cluster
|
Single Family Dwelling Attached: Townhouses
|
Maximum density (du/net acre)
|
15
|
15
|
15
|
15
|
15
|
Minimum lot size (sq. ft.)
|
5,000
|
5,000
2,500 each du
|
4,000
|
2,500 each du
|
7,500
|
Maximum structure height (ft.)
|
35
|
35
|
35
|
35
|
35
|
Maximum structure length (ft.)
|
None
|
None
|
None
|
None
|
200
|
Minimum lot width (ft.)
|
50
|
50
|
40
|
See Section 47-18.9
|
50
|
Minimum floor area (sq. ft.)
|
750 each du
|
400 each du
|
1,000
|
750 each du
|
750 each du
|
Minimum front yard (ft.)
|
25
|
25
|
25
|
25
|
25
|
Minimum corner yard (ft.)
|
25% of lot width but not less than 10 ft. nor greater than 25 ft.
20 ft. when abutting a waterway
|
25% of lot width but not less than 10 ft. nor greater than 25 ft.
20 ft. when abutting a waterway
|
See Section 47-18.38
20 ft. when abutting a waterway
|
25% of lot width but not less than 10 ft. nor greater than 25 ft.
20 ft. when abutting a waterway
|
25% of lot width but not less than 10 ft. nor greater than 25 ft.
20 ft. when abutting a waterway
|
Minimum side yard (ft.)
|
5 ft. - up to 22 ft. in height for one or two story buildings
Where a building exceeds 22 ft. in height that portion of the building above 22 ft.
shall be set back an additional foot per foot of additional height
20 ft. when abutting a waterway
|
Same as single family requirement
20 ft. when abutting a waterway
|
See Section 47-18.38
20 ft. when abutting a waterway
|
See Section 47-18.9
20 ft. when abutting a waterway
|
See Section 47-18.33
20 ft. when abutting a waterway
|
Minimum rear yard (ft.)
|
15
20 ft. when abutting a waterway
|
15
20 ft. when abutting a waterway
|
15
20 ft. when abutting a waterway
|
See Section 47-18.9
20 ft. when abutting a waterway
|
20
|
Minimum distance between buildings (ft.)
|
None
|
None
|
None
|
None
|
None
|