§ 47-7.30. Table of dimensional requirements for the I district. (Note A)


Latest version.
  • Requirements I
    Maximum height (ft.) 150
    Minimum lot size
    Minimum lot width
    None
    Maximum FAR None
    Minimum front yard (ft.):
    When contiguous to residential property 30
    All others  5*
    Minimum side yard (ft.):
    When contiguous to residential property 30
    All others All side yards abutting a street: 5 ft.

    All other side yards: None except when any portion of a structure is greater in height than 100 ft. up to maximum height of 150 ft., that portion of the structure shall be set back an additional 1 ft. for each 1 ft. of building height over 100 ft.
    Minimum rear yard (ft.):
    When contiguous to residential property 30
    All others All rear yards abutting a street: 5 ft.

    All other rear yards: None except when any portion of a structure is greater in height than 100 ft. up to maximum height of 150 ft., that portion of the structure shall be set back an additional 1 ft. for each 1 ft. of building height over 100 ft.

     

    Note A: Dimensional regulations may be subject to additional requirements, see Section 47-23, Specific Location Requirements, and Section 47-25, Development Review Criteria.

    *Where the height of a building exceeds nine feet measured from the ground floor elevation, that portion of the building may extend into the front yard area.

(Ord. No. C-97-19, § 1(47-7.5), 6-18-97)