§ 47-13.31. Table of Dimensional Requirements for the NWRAC-MU District.  


Latest version.
  • REQUIREMENTS (Note A) NWRAC-MUne NWRAC-MUe NWRAC-MUw
    Max. Height
    (Note B)
    120 ft 65 ft 45 ft
    Min Lot Size None
    Min. Lot Width
    Max FAR
    Density None
    Yard Requirements (Note B & C) (*) 0 ft (Primary Street)
    5 ft (Secondary Street & NW 7 th Ave)
    When abutting residential 15 ft 15 ft 15 ft
    (**) Min. Shoulder Height 25 ft (2 Stories) min
    (**) Max. Shoulder Height 65 ft (5 Stories) max
    When abutting residential 45 ft max
    (**) Tower Stepback
    (**) Tower
    Floorplate
    Separation
    Floorplate Max Floorplate Max Side Rear Stepback Min
       Non-Residential ≤16,000 sf ≤16,000 sf 20 ft min
    16,001—20,000 sf 16,001—20,000 sf 25 ft min
    20,001—32,000 sf 20,001—32,000 sf 30 ft min
       Residential ≤ 8,000 sf ≤ 8,000 sf 20 ft min
    8,001—10,000 sf 8,001—10,000 sf 25 ft min
    10,001—12,000 sf 10,001—12,000 sf 30 ft min
    10,001—12,000 sf 10,001—12,000 sf 30 ft min

     

    Note A: Dimensional requirements are subject to the intent of the NWRAC-MU Illustration of Design Standards. In the event of a conflict the NWRAC-MU Illustration of Design Standards shall take precedence.
    Note B: An increase in height shall be permitted as follows:
    NWRAC-MUe east of NW 2 nd Avenue: up to one hundred twenty (120) feet,
    NWRAC-MUe west of NW 2 nd Avenue: up to one hundred ten (110) feet when approved by the city commission in accordance with the performance standards provided in Section 47-13.52.B,
    NWRAC-MUw: up to sixty-five (65) feet when approved by the city commission in accordance with the performance standards provided in Section 47-13.52.B.
    Note C: A side yard is not required unless abutting residential property.
    (*) Yard setback is based on the adopted street cross-sections and shall correspond to those as indicated in the NW-RAC Illustrations of Design Standards.
    (**) May be modified if alternative design is found to achieve the underlying intent of the standards as provided in the NWRAC-MU Illustration of Design Standards.

     

( Ord. No. C-10-50, § 1, 1-4-11 ; Ord. No. C-14-51, § 1, 1-21-15 )